Operational Procedures: Minima and planningA free chapter of the 070 notes

Part 2 of 3 in the 070 Operational Procedures notes.
Free to read, exactly as sold.

Get all 13 chapters as a PDF

Part 2

Minima and planning

Approach classification · Aerodrome minima · Alternates · Fuel

2.1 Approach classification since 2022

Regulation (EU) 2021/2237: All-weather operations

Fig. 2.1 The classification in force since 30 October 2022. The boundary between Type A and Type B is a decision height of 250 ft.
ClassCriterionExamples
Type AMDH or DH at or above 250 ftNDB, VOR, LOC, RNP APCH to LNAV or LNAV/VNAV, circling
Type BDH below 250 ftILS, MLS, GLS, RNP AR. Subdivided into CAT I, CAT II, CAT III
CategoryDecision heightOrder of magnitude of RVR
CAT INot lower than 200 ftFrom 550 m
CAT IIBetween 100 and 200 ftFrom 300 m
CAT IIIBelow 100 ft, or no decision heightDown to the European minimum of 75 m

Aircraft approach categories

CategoryVAT: 1.3 × VSOMaximum speed, circlingExamples
ALess than 91 kt100 ktLight aircraft
B91 to 120 kt135 ktRegional turboprops
C121 to 140 kt180 ktBusiness jets, narrow-bodies
D141 to 165 kt205 ktWide-bodies
E166 to 210 kt240 ktRare in civil transport

The category is determined at maximum certified landing mass, in landing configuration. It drives circling minima and protection areas. VAT is 1.3 × VSO or 1.23 × VS1g, and where both exist the higher result is used (CAT.OP.MPA.320). The circling speeds are the PANS-OPS values, as published in national AIPs.

Lowest DH and MDH

A DH or MDH may not be lower than the highest of: the OCH for the aircraft category, the published DH or MDH, the system minimum below, the runway-type minimum, and the minimum in the flight manual if one is stated (AMC3 CAT.OP.MPA.110).

FacilityLowest DH/MDH
ILS, MLS, GLS · PAR · LPV *200 ft
LP · LNAV · LNAV/VNAV · LOC with or without DME · VOR/DME · SRA ending at ½ NM250 ft
VOR · NDB/DME · SRA ending at 1 NM300 ft
NDB · VDF · SRA ending at 2 NM or more350 ft

* LPV: 200 ft only if the published FAS data block sets a vertical alert limit of at most 35 m, otherwise 250 ft. The runway-type minimum is 200 ft for a CAT I precision runway and 250 ft for a non-precision runway.

Circling minima

Aeroplane categoryABCD
Lowest circling MDH400 ft500 ft600 ft700 ft
Lowest meteorological visibility1 500 m1 600 m2 400 m3 600 m

The circling MDH is the highest of the published circling OCH, the figure above and the DH or MDH of the preceding instrument approach. The MDH is referenced to the aerodrome elevation, the MDA to mean sea level, and the visibility is the meteorological visibility, not an RVR (AMC7 CAT.OP.MPA.110).

2.2 Aerodrome minima and low visibility take-off

Low visibility take-off

LVTO is a take-off with an RVR below the normal minima. It requires an approval and imposes increasing requirements for runway lighting, centreline marking, RVR coverage and crew training as the value decreases.

Take-off facilitiesMinimum RVR or VIS
No lights or markings, day only500 m, the pilot being able to identify the take-off surface continuously and keep directional control
Day, runway edge lights or centreline markings or centreline lights400 m
Night, end lights and edge lights or centreline lights400 m

These are the values without an LVTO approval (AMC1 CAT.OP.MPA.110). An aeroplane that can stop or continue to 1 500 ft after an engine failure at any point uses them; otherwise the RVR also depends on the height at which the engine is assumed to fail, from 400 m up to 1 500 m.

With an LVTO approvalFacilities
300 m, day or nightCentreline markings and edge lights; at night also end lights or centreline lights
150 mCentreline markings, end lights, edge lights and centreline lights
125 mAs for 150 m, with edge lights spaced 60 m or less and centreline lights spaced 15 m or less
Below 125 mCentreline lights at 15 m or less, an ILS localiser to category III standard if one is used, and an aeroplane certified for it. The RVR is not below the AFM minimum or 75 m.

A specific approval is needed for any take-off in an RVR below 400 m (SPA.LVO.100). Low visibility conditions are those with an RVR below 550 m.

CAT II and CAT III minima

CAT II: DHRVR, categories A to CRVR, category D
100 to 120 ft300 m300 m with autoland or HUDLS to touchdown, otherwise 350 m
121 to 140 ft400 m400 m
141 to 199 ft450 m450 m

The CAT II DH comes from a radio altimeter and is not lower than the AFM minimum, the OCH, the DH the crew is qualified for, or 100 ft (AMC1 SPA.LVO.100(b)).

CAT III: DHRoll-out controlRVR
50 to 99 ftNot required175 m
0 to 49 ft, or no DHFail-passive125 m
0 to 49 ft, or no DHFail-operational75 m

A fail-passive system leaves no significant out-of-trim condition or flight path deviation after a failure, but the landing is not completed automatically: the pilot takes over. After a failure below alert height a fail-operational system lets the approach, flare and landing be completed automatically. A lower RVR, never below 75 m, applies if the AFM states it for a fail-passive or HUD roll-out system. A no-DH approach also needs the AFM to allow it and a crew qualified for it (AMC2 SPA.LVO.100(b)).

OperatorAircraftCrew
Specific approval (SPA.LVO.100); procedures; MEL and maintenance programme changed; aerodromes and procedures suitable; safety assessment and performance indicators Certified for the intended operation; DH from a radio altimeter or equivalent; fail-passive or fail-operational class as the minima require Initial and recurrent training and checking, including abnormal and emergency procedures, tailored to the technology; records kept (SPA.LVO.120)

2.3 Planning minima and alternates

Destination and alternates

  • Forecast conditions must meet the applicable minima over a window bracketing the estimated time of arrival, commonly ± 1 hour.
  • Two alternates are required when the destination forecast is below planning minima, or when no meteorological information is available.
  • For an alternate, the margin is added to the published minima of the available approach. The more precise the approach, the smaller the margin.
Approach available at the alternatePlanning minima, basic fuel scheme (AMC6 CAT.OP.MPA.182)
Type BDA/H + 200 ft · RVR/VIS + 800 m
Type ADA/H or MDA/H + 400 ft · RVR/VIS + 1 500 m
CirclingMDA/H + 400 ft · VIS + 1 500 m

These apply to a destination alternate, a fuel en-route alternate and an isolated destination. Older questions still use the former table: CAT II or III assessed against CAT I minima, CAT I against non-precision minima, non-precision minima increased by a margin.

2.4 The approach ban

The rule known as the approach ban determines when a deterioration in conditions prevents continuation. The pivot point is 1 000 ft above the aerodrome.

Fig. 2.2 The approach ban on a 3° path (vertical scale exaggerated). Below minima before 1 000 ft above the aerodrome, the approach is not continued; after that point it may be continued to DA/H or MDA/H, where the required visual reference decides.

2.5 Fuel and isolated aerodromes

An isolated aerodrome is one for which no usable alternate exists, given the range of the aeroplane.

Fuel components

TaxiFrom start-up to brake release
TripFrom brake release to landing at destination
ContingencyCovers deviations from planned data. Reducible to 3 % with a dedicated fuel en-route alternate.
AlternateFrom the missed approach at destination to landing at the alternate
Final reserve30 minutes at holding speed at 1 500 ft above the alternate for a turbine, 45 minutes for a piston engine
AdditionalRequired by a specific scenario, such as engine failure or depressurisation en route
ExtraAt the commander's sole discretion

What the other parts of 070 cover

  1. Part 1

    General requirements

    The ICAO and Part-CAT framework, the operations manual, safety and survival equipment, oxygen, mandatory avionics, long-range flights and NAT airspace.

    071 01
  2. Part 3

    Special procedures and hazards

    Icing, contaminated runways, wind shear, wake turbulence, bird strike, fire and smoke, depressurisation, fuel jettisoning, security, dangerous goods.

    071 02

Revise it with the notes

Pay once, no subscription.

  • All 13 subjects

    €79 once

    + 2 months of all questions

    The notes of every ATPL subject, PDF and screen edition, yours for life.

  • 070 Operational Procedures

    €15.90 once

    + 1 month of its questions

    PDF and screen edition, yours for life.
    Updates included for 1 year.

The 070 Operational Procedures page, its contents and its exam traps →

Starter Kit

One full chapter of every subject, free.

Not ready for the pack? Get the Starter Kit: one complete chapter from each of the 13 ATPL(A) subjects, in one PDF.

Updated

€79 All 13 subjects